Ausstattungsliste: Rupert Neve 542
Specification | |
Type | 500 Series Tape Emulator |
Line Amp Specifications (Measurements with tape circuit disengaged) | Noise |
Measured at Main Output, un-weighted, 20Hz-22kHz, Input Terminated 40 Ohms. | |
Unity Gain Better than -100dBu | |
Frequency Response | Measured at +10dBu, trim at unity. |
Main Output +/- 0.25dB from 5Hz to 60Khz -2dB @ 120KHz | |
Maximum Output Level 23.25dBu | |
Total Harmonic Distortion and Noise | @ 1kHz, +20dBu output level Better than 0.0025% |
@ 20Hz, +20dBu output level 0.07% Typical (2nd and 3rd harmonic) | |
Tape FX Specifications Noise | Measured at Main Output, un-weighted, 20Hz-22kHz, Input Terminated 40 Ohms. |
Saturation @ minimum Better than -100dBu | |
Saturation @ maximum Better than -100dBu | |
Frequency Response | 15 IPS, Input @ -0 dBu -3dBu @ 28kHz |
Saturation @ minimum 0dBu @ 10Hz | |
+5dBu Peak @ 60Hz | |
Saturation @ maximum -3dBu @ 20kHz | |
-3dBu @ 12.5Hz | |
+2.4dBu Peak @ 60Hz | |
30 IPS, Input @ -0 dBu -3dBu @ 120kHz | |
Saturation @ minimum -3dBu @ 10Hz +3.15dBu Peak @ 125Hz | |
Saturation @ maximum -3dBu @ 100kHz | |
-3dBu @ 12.5Hz | |
+1.3dBu Peak @ 110Hz | |
Total Harmonic Distortion and Noise | Refer to sweeps on page10 |
15 IPS, Input @ -0 dBu 0.4% @ 3kHz to 1% @ 175Hz typical | |
Saturation @ minimum Greater than 1% below 175Hz typical | |
Saturation @ maximum 1% at 6kHz typical | |
0.3% @ 1kHz to 3% @ 50Hz typical | |
30 IPS, Input @ -0 dBu 1% at 1kHz typical | |
Saturation @ minimum 0.6% @ 400Hz 5% @ 20Hz typical | |
Saturation @ maximum 1.5% @ 20kHz to 0.4% @ 1kHz typical | |
0.4% @ 1kHz to 2 %@ 50Hz typical | |
Power requirements | Supplied by 500 series rack with 110-125 mA @ +/- 16V DC |