TECHNICAL SPECIFICATION | |
Dimensions | 380 x 600 x 360mm (w x h x d) |
Weight | 39kg / 86lb |
Drivers | Low Frequency 1 x 250mm(10″) |
Mid | 1 x 75mm (3”) soft dome |
High Frequency | soft dome 1 x 28mm (1 1/8″) |
Maximum SPL | 115.5 dB continuous pink noise @ 1m Leq 1 minute. 121.5 dB continuous pink noise per pair @ 1m Leq 1 minute |
Frequency Response | 34Hz – 20kHz ±2dB / 30Hz – 22kHz -6 dB |
INPUT | |
Connector | XLR3 type-Female |
Impedance | 10k Electronically balanced with RF filters |
Wiring | Pin 1 ground, Pin 2 hot, Pin 3 cold |
Sensitivity | Rear mounted 10 position rotary switch calibrated in 2dB steps |
Minimum sensitivity | +4dBu for 100dB SPL @ 1m |
Maximum sensitivity | -14dBu for 100 dB SPL @ 1m |
FILTERS | |
Subsonic | -3dB @ 14Hz, 24dB/oct |
Crossover Point | 650Hz, 2k5H, 24dB/oct. |
User LF EQ | 4 position rear mounted selector to select FLAT for normal use. -9dB and -3dB for cut below 100Hz, +1dB for lift above 80Hz. |
User MF EQ | 3 position rear mounted switch to select FLAT for normal use, CUT/LIFT +/-1dB for 650Hz to 2k5Hz. |
User HF EQ | 3 position rear mounted switch to select FLAT for normal use, CUT/LIFT +/-1dB for 2k5Hz to 40kHz. |
POWER AMPLIFIER | |
LF output power | > 700W rms continuous (Note 1) |
Mid Output | > 150W rms continuous (Note 1) |
HF output power | > 150W rms continuous (Note 1) |
THD | < 0.03% at levels up to 1dB below clip, 20Hz – 20kHz. typ 0.005% @ 20W rms 1kHz. |
Hum & Noise | > -100dB referred to clip |
Note | The continuous rating is for a period not exceeding 5 minutes with unrestricted airflow (100mm clearance) around the amplifier rear panel and ambient temperatures is <30 o C |
INDICATION | |
Power on | Front mounted LED (flashing blue) indicates power applied and warm-up cycle. |
Optimum Performance | Front mounted LED lights constant blue. |
Overload | Front mounted LED flashes red 0.5dB below signal clip. |
Thermal Protection | Front mounted LED turns red, signal is muted and amplifier switches to standby mode during thermal protection cooling cycle. Normal operation resumes when amplifier temperature drops by 20 o C. |
POWER REQUIREMENTS | |
Voltage | Set by internal plugs: nominal 115V or 230V @ 50-60Hz AC. |
230V setting | Min 160V (restricted output power): Max 263V |
115V setting | Min 80V (restricted output power): Max 132V |
CONSUMPTION | |
Quiescent | 72W, typical use 110W. |
Note | 0dBu = 775mV into open circuit. |