Ausstattungsliste: Quested Monitoring Systems V2108
TECHNICAL SPECIFICATION | |
Dimensions | 340 x 400 x 365mm (w x h x d) |
Weight | 23kg / 50.5lb |
Drivers | Low Frequency 1 x 200mm(8″) LF |
High Frequency | soft dome – 1 x 28mm (1. 1/8″) |
Maximum SPL | 108.5 dB continuous pink noise @ 1m Leq 1 minute. 114 dB per pair continuous pink noise @ 1m Leq 1 minute |
Frequency Response | 45 Hz – 20 kHz ± 2dB / 38 Hz- 22 kHz -6 dB |
INPUT | |
Connector | XLR3 type-Female |
Impedance | 10k Electronically balanced with RF filters |
Wiring | Pin 1 ground, Pin 2 hot, Pin 3 cold |
Sensitivity | Rear mounted 10 position rotary switch calibrated in 2dB steps |
Minimum sensitivity | +7dBu for 100dB SPL @ 1m |
Maximum sensitivity | -11dBu for 100 dB SPL @ 1m |
FILTERS | |
Subsonic | Subsonic: -3dB @ 20Hz, 24dB/oct |
Crossover Point | 1k4H, 24dB/oct |
User LF EQ | 4 position rear mounted selector to select FLAT for normal use. -3/- 9dB for cut below 40Hz, 0, +1dB. |
User HF EQ | 3 position rear mounted switch to select FLAT for normal use, CUT/LIFT +/-1dB above 2k5Hz. |
POWER AMPLIFIER | |
HF output power | > 200W rms continuous (Note 1) |
LF output power | > 200W rms continuous (Note 1) |
THD | < 0.03% at levels up to 1dB below clip, 20Hz – 20kHz. typ 0.005% @ 20W rms 1kHz. |
Hum & Noise | > -100dB referred to clip |
Note | The continuous rating is for a period not exceeding 5 minutes with unrestricted airflow (>100mm clearance) around the amplifier rear panel and ambient temperatures is <30 Degrees C |
INDICATION | |
Power on | Front mounted LED (flashing blue) indicates power applied and warm-up cycle. |
Optimum Performance | Front mounted LED lights constant blue. |
Overload | Front mounted LED flashes red (HF 1dB below signal clip, LF 2dB below signal clip) |
Thermal Protection | Front mounted LED turns red, signal is muted and amplifier switches to standby mode during thermal protection cooling cycle. Normal operation resumes when amplifier temperature drops by 20 o C. |
POWER REQUIREMENTS | |
Voltage | Set by internal plugs: nominal 115V or 230V @ 50-60Hz AC. |
230V setting | Min 160V (restricted output power): Max 263V |
115V setting | Min 80V (restricted output power): Max 132V |
CONSUMPTION | |
Quiescent | 32W, Typical use 92W. |